mobile background
JetBuster

Zone Response System Based on Simultaneous Discharge Valve Technology




The core of Jet Buster lies in its simultaneous discharge valve technology.
When the upper closed-type head is activated, 

the lower open-type head discharges water at the same time, 

expanding the range of initial fire response.
This structure minimizes discharge blind spots and 

enables rapid response to adjacent areas as well.


JETBUSTER dramatically improves the non-operation of sprinklers due to skipping phenomenon. Existing sprinklers failed to suppress the initializer due to chronic skipping phenomenon* and the sprinkler did not operate even if it is in normal condition. We use our own developed hydraulic control technology to implement a reliable sprinkler system that is independent of skipping phenomenon.


The current sprinkler system combines hydraulic sensing technology that automatically detects water flow to improve operational accuracy. Existing sprinklers were operated only by fire heat, but JETBUSTER allows the main sprinkler head to detect fire heat and simultaneously spray form all dependent open sprinklers when operated to increase fire extinguishing power.


*Skipping phenomenon

Due to the impingement of water droplets form previously activated sprinklers or condensation of water vapor onto the next sprinkler's fusible elements head, cooling the air temperature, which interferes with the other sprinkler's operation.


60% of the sprinkler does not operate properly on the fire

79% of Sprinkler malfunctioning is due to the skipping phenomenon


Jetbuster - Technology

USUALLY


1. Water controls pressure balance, holding pressure sensor

2. Pressure sensor blocks bottom pipe water flow

FIRE


1. Upper closed-type sprinkler head to be activated for water spray.

2. Pushed-up piston valve opens the water path to the open type sprinkler.

3. Open type sprinkler starts spraying water sequentially.

JETBUSTER BUSINESS BACKGROUND

About KRW 3 trillion in property damage caused by fire accidents and about 10,000 casualties in the past five years

The rate of sprinkler non-operating in all fire accidents is about 60%

Property Damage

3 trillion

Property Damage

3 trillion

Damage of Human Life

10,000

Damage of Human Life

10,000

60%

of all Fire Accidents

60%

of all Fire Accidents

* 2020 Fire Statistics Yearbook of Fire Service

79% of the sprinkler malfunctioning is due to the skipping phenomenon

*2017 NEPA Research / International Fire Protection Association 

79%






Installation Benefits







JETBUSTER is a sprinkler system that links closed-type main heads with open-type auxiliary heads to enable rapid initial fire response and effective simultaneous water discharge in the event of a fire.
It allows flexible design and stable water flow even in spaces with many obstructions, areas with complex layouts, and locations where securing ceiling height is critical—enhancing both fire suppression performance and installation efficiency.











1. Rapid Initial Response

Enables quick initial water discharge through linked operation of auxiliary heads.



2. Enhanced Fire Suppression Performance

Delivers strong extinguishing performance by addressing sprinkler blind spots.



3. Simultaneous Discharge / Fire Spread Control

Suppresses fire spread through simultaneous discharge from multiple heads.



4. Effective in Obstructed Environments

Performs effectively even in spaces crowded with racks, equipment, and piping.



5. Flexible Customized Design

Adapts flexibly to various structures and irregular spaces.



6. Cost Reduction

Reduces key material usage and enables more economical piping configurations.



7. Reduced Ceiling Space Requirements

Minimizes ceiling space occupancy, allowing for more efficient installation.

Key Applications

Logistics Center / Factory


Rack-type warehouses contain large amounts of combustibles and obstructions, making the application of conventional systems with multiple installation constraints limited.


JETBUSTER’s simultaneous discharge function of auxiliary heads minimizes the impact of obstructions and enables rapid, powerful water discharge, making it well suited for rack-type warehouses with high fire loads.


Underground parking lot  /  Electric vehicle parking area


Electric vehicle fires can spread rapidly due to thermal runaway, and conventional sprinkler systems may be delayed in providing an effective initial response.
JETBUSTER’s simultaneous discharge function of auxiliary heads enables wide-area water discharge immediately upon fire outbreak, effectively suppressing rapid fire spread and making it well suited for EV charging areas.


House / Outdoor unit room


Electric vehicle fires can spread rapidly due to thermal runaway, and conventional sprinkler systems may be delayed in providing an effective initial response.
JETBUSTER’s simultaneous discharge function of auxiliary heads enables wide-area water discharge immediately upon fire outbreak, effectively suppressing rapid fire spread and making it well suited for EV charging areas.